142 research outputs found

    Assessment of pulse rate variability by the method of pulse frequency demodulation

    Get PDF
    BACKGROUND: Due to its easy applicability, pulse wave has been proposed as a surrogate of electrocardiogram (ECG) for the analysis of heart rate variability (HRV). However, its smoother waveform precludes accurate measurement of pulse-to-pulse interval by fiducial-point algorithms. Here we report a pulse frequency demodulation (PFDM) technique as a method for extracting instantaneous pulse rate function directly from pulse wave signal and its usefulness for assessing pulse rate variability (PRV). METHODS: Simulated pulse wave signals with known pulse interval functions and actual pulse wave signals obtained from 30 subjects with a trans-dermal pulse wave device were analyzed by PFDM. The results were compared with heart rate and HRV assessed from simultaneously recorded ECG. RESULTS: Analysis of simulated data revealed that the PFDM faithfully demodulates source interval function with preserving the frequency characteristics of the function, even when the intervals fluctuate rapidly over a wide range and when the signals include fluctuations in pulse height and baseline. Analysis of actual data revealed that individual means of low and high frequency components of PRV showed good agreement with those of HRV (intraclass correlation coefficient, 0.997 and 0.981, respectively). CONCLUSION: The PFDM of pulse wave signal provides a reliable assessment of PRV. Given the popularity of pulse wave equipments, PFDM may open new ways to the studies of long-term assessment of cardiovascular variability and dynamics

    What parameters affect left ventricular diastolic flow propagation velocity? in vitro studies using color m-mode doppler echocardiography

    Get PDF
    BACKGROUND: Insufficient data describe the relationship of hemodynamic parameters to left ventricular (LV) diastolic flow propagation velocity (Vp) measured using color M-mode Doppler echocardiography. METHODS: An in vitro LV model used to simulate LV diastolic inflow with Vp measured under conditions of varying: 1) Stroke volume, 2) heart rate (HR), 3) LV volume, 4) LV compliance, and 5) transmitral flow (TMF) waveforms (Type 1: constant low diastasis flow and Type 2: no diastasis flow). RESULTS: Univariate analysis revealed excellent correlations of Vp with stroke volume (r = 0.98), LV compliance (r = 0.94), and HR with Type 1 TMF (r = 0.97). However, with Type 2 TMF, HR was not associated with Vp. LV volume was not related to Vp under low compliance, but inversely related to Vp under high compliance conditions (r = -0.56). CONCLUSION: These in vitro findings may help elucidate the relationship of hemodynamic parameters to early diastolic LV filling

    Identifying Isolated Systolic Hypertension From Upper-Arm Cuff Blood Pressure Compared With Invasive Measurements

    Get PDF
    Isolated systolic hypertension (ISH) is the most common form of hypertension and is highly prevalent in older people. We recently showed differences between upper-arm cuff and invasive blood pressure (BP) become greater with increasing age, which could influence correct identification of ISH. This study sought to determine the difference between identification of ISH by cuff BP compared with invasive BP. Cuff BP and invasive aortic BP were measured in 1695 subjects (median 64 years, interquartile range [55-72], 68% male) from the INSPECT (Invasive Blood Pressure Consortium) database. Data were recorded during coronary angiography among 29 studies, using 21 different cuff BP devices. ISH was defined as ≥130/<80 mm Hg using cuff BP compared with invasive aortic BP as the reference. The prevalence of ISH was 24% (n=407) according to cuff BP but 38% (n=642) according to invasive aortic BP. There was fair agreement (Cohen κ, 0.36) and 72% concordance between cuff and invasive aortic BP for identifying ISH. Among the 28% of subjects (n=471) with misclassification of ISH status by cuff BP, 20% (n=96) of the difference was due to lower cuff systolic BP compared with invasive aortic systolic BP (mean, -16.4 mm Hg [95% CI, -18.7 to -14.1]), whereas 49% (n=231) was from higher cuff diastolic BP compared with invasive aortic diastolic BP (+14.2 mm Hg [95% CI, 11.5-16.9]). In conclusion, compared with invasive BP, cuff BP fails to identify ISH in a sizeable portion of older people and demonstrates the need to improve cuff BP measurements

    Influence of Age on Upper Arm Cuff Blood Pressure Measurement

    Get PDF
    Blood pressure (BP) is a leading global risk factor. Increasing age is related to changes in cardiovascular physiology that could influence cuff BP measurement, but this has never been examined systematically and was the aim of this study. Cuff BP was compared with invasive aortic BP across decades of age (from 40 to 89 years) using individual-level data from 31 studies (1674 patients undergoing coronary angiography) and 22 different cuff BP devices (19 oscillometric, 1 automated auscultation, 2 mercury sphygmomanometry) from the Invasive Blood Pressure Consortium. Subjects were aged 64±11 years, and 32% female. Cuff systolic BP overestimated invasive aortic systolic BP in those aged 40 to 49 years, but with each older decade of age, there was a progressive shift toward increasing underestimation of aortic systolic BP (P<0.0001). Conversely, cuff diastolic BP overestimated invasive aortic diastolic BP, and this progressively increased with increasing age (P<0.0001). Thus, there was a progressive increase in cuff pulse pressure underestimation of invasive aortic PP with increasing decades of age (P<0.0001). These age-related trends were observed across all categories of BP control. We conclude that cuff BP as an estimate of aortic BP was substantially influenced by increasing age, thus potentially exposing older people to greater chance for misdiagnosis of the true risk related to BP

    Early diastolic filling dynamics in diastolic dysfunction

    Get PDF
    BACKGROUND: The aim of the study was to determine the relationship between the rate of peak early mitral inflow velocity and the peak early diastolic mitral annular tissue velocities in normal controls and to compare them with subjects with diastolic dysfunction. METHODS: The relationship between early passive diastolic transmitral flow and peak early mitral annular velocity in the normal and in diastolic dysfunction was studied. Two groups comprising 22 normal controls and 25 patients with diastolic dysfunction were studied. RESULTS: Compared with the normal group, those with diastolic dysfunction had a lower E/A ratio (0.7 ± 0.2 vs. 1.9 ± 0.5, p < 0.001), a higher time-velocity integral of the atrial component (11.7 ± 3.2 cm vs. 5.5 ± 2.1 cm, p < 0.0001), a longer isovolumic relaxation time 73 ± 12 ms vs. 94 ± 6 ms, p < 0.01 and a lower rate of acceleration of blood across the mitral valve (549.2 ± 151.9 cm/sec(2 )vs. 871 ± 128.1 cm/sec(2), p < 0.001). They also had a lower mitral annular relaxation velocity (Ea) (6.08 ± 1.6 cm/sec vs 12.8 ± 0.67 cm/sec, p < 0.001), which was positively correlated to the acceleration of early diastolic filling (R = 0.66), p < 0.05. CONCLUSIONS: This investigation provides information on the acceleration of early diastolic filling and its relationship to mitral annular peak tissue velocity (Ea) recorded by Doppler tissue imaging. It supports not only the premise that recoil is an important mechanism for rapid early diastolic filling but also the existence of an early diastolic mechanism in normal

    Dual isotope analyses indicate efficient processing of atmospheric nitrate by forested watersheds in the northeastern U.S.

    Get PDF
    Author Posting. © Springer, 2008. This is the author's version of the work. It is posted here by permission of Springer for personal use, not for redistribution. The definitive version was published in Biogeochemistry 90 (2008): 15-27, doi:10.1007/s10533-008-9227-2.Nitrogen from atmospheric deposition serves as the dominant source of new nitrogen to forested ecosystems in the northeastern U.S.. By combining isotopic data obtained using the denitrifier method, with chemistry and hydrology measurements we determined the relative importance of sources and control mechanisms on nitrate (NO3-) export from five forested watersheds in the Connecticut River watershed. Microbially produced NO3- was the dominant source (82-100%) of NO3- to the sampled streams as indicated by the δ15N and δ18O of NO3-. Seasonal variations in the δ18O-NO3- in streamwater are controlled by shifting hydrology and temperature affects on biotic processing, resulting in a relative increase in unprocessed NO3- export during winter months. Mass balance estimates find that the unprocessed atmospherically derived NO3- stream flux represents less than 3% of the atmospherically delivered wet NO3- flux to the region. This suggests that despite chronically elevated nitrogen deposition these forests are not nitrogen saturated and are retaining, removing, and reprocessing the vast majority of NO3- delivered to them throughout the year. These results confirm previous work within Northeastern U.S. forests and extend observations to watersheds not dominated by a snow-melt driven hydrology. In contrast to previous work, unprocessed atmospherically derived NO3- export is associated with the period of high recharge and low biotic activity as opposed to spring snowmelt and other large runoff events.This work was funded by an EPA STAR Fellowship (FP-91637501-1) and a grant from QLF/The Sound Conservancy to RTB
    • …
    corecore